Sweep & inspection
Caps & crowns
Flue relining
Masonry repair
Gas fireplace serviceLevel 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
DuraFlex Chimney Cleaning in Concourse, NY
Chimney Sweep Tremont provides independent DuraFlex service across Concourse, from Level 2 inspections of shared masonry stacks to cap and multi-flue cap work on pre-war rooftops. The one thing that makes our DuraFlex work here different: in Concourse, the stainless liner is rarely the part that fails first. The crown and top plate it terminates on usually are.

We’re an independent DuraFlex service provider, not affiliated with or authorized by the manufacturer. What we bring is focused familiarity with the line – the SW smooth-wall kits, the Pro series, the insulated systems, and the multi-flue caps – plus quality parts that fit old oval and oversize flues. Concourse buildings ask a lot of a liner. Our technicians have up to 14 years of experience reading what a shared stack has been through.
Call (844) 979-4331. We answer 24/7. Fast dispatch from 7am to 7pm, Sunday through Friday.
Why Concourse Residents Choose Us for DuraFlex Service
Most chimney companies in this part of the Bronx are set up for single-family houses with wood-burning fireplaces. Concourse isn’t that. It’s four-to-six story brick walk-ups built between 1900 and 1930, with chimney stacks shared by several apartments and flues that now vent gas boilers, gas water heaters, or nothing at all. The DuraFlex work here happens apartment by apartment, with landlords and supers involved, and it has to be documented well enough that a building owner can act on it.
We work with professional-grade brands – DuraFlex, HeatShield, Gelco, Olympia Chimney, Famco, Copperfield – because on a listed liner system, a mismatched cap or top plate creates problems no amount of labor skill corrects. One company handles the whole chimney system in a Concourse building, from the basement cleanout door to the crown, so nothing gets lost between a sweep and a roofer. Chimney-only focus means our technicians have seen these stacks before.
Styles & brands we work with
- Sweep & inspection
- Caps & crowns
- Flue relining
- Masonry repair
- Gas fireplace service
Common DuraFlex Chimney Cleaning Problems We Solve in Concourse
The DuraFlex failures we see in Concourse tend to trace back to how these buildings were converted, not to the stainless itself. Here’s what comes up most.
- Joint separation on a repurposed flue. A smooth-wall DuraFlex liner installed for a wood appliance but now serving a gas boiler can develop gaps at the seams and crimp damage if it was sized or supported for the original use. The tell is CO spillage at the draft hood and visible seams you can spot with a camera. In a shared Concourse stack, that’s a whole-column concern.
- Loose or corroded top plates. New York’s freeze-thaw winters work on the cap and top plate connection at the termination even when the liner below is fine. Water tracks down the annular space and shows up as efflorescence on the brick a floor or two down.
- Unsealed coal-era cleanout doors. Many Concourse basements still have the original cleanout doors, never properly sealed. A DuraFlex liner installed without a sealed bottom tee collects soot and creosote right at that gap.
- Failed multi-flue cap screens. Crowded pre-war rooftops take wind and ice, and cap screens tear or edges lift. Rain then enters flues serving gas water heaters in several apartments at once.
- Blocked or crushed liner sections. Debris, an old bird nest, or a section crushed during an earlier install restricts draft. This is the case where cleaning alone won’t solve it, and the liner section has to be replaced.
DuraFlex Service in Concourse: What Local Conditions Mean for Your Equipment
Concourse stacks were built for coal and later repurposed for gas, and that history lives on the roof. Many DuraFlex liners here terminate at a top plate sitting on a crown that was never designed to carry a stainless liner – and the crown, not the liner, is often the first failure point. A crown that’s cracked from twenty freeze-thaw cycles lets water in at the exact spot where the top plate seals. The liner tests sound. The termination doesn’t.
That changes how a cleaning visit should go in a building like the ones off the Grand Concourse near 161st Street. It’s not enough to run a brush and leave. The technician needs to be on the roof checking the crown, the top plate, and the cap, and in the basement checking that the cleanout is sealed. When one apartment reports smoke or a CO alarm, the flue column gets traced top to bottom, because a defect on one floor is a building-wide safety issue. If you’re on a DuraFlex system and you’ve only ever had a sweep, this is the inspection you actually want.
DuraFlex Models & Products We Service in Concourse
We service DuraFlex SW smooth-wall flexible stainless liner kits, the DuraFlex Pro flexible chimney liner series, DuraFlex insulated flexible liner systems, and DuraFlex multi-flue and custom chimney caps. In a Concourse walk-up, that range matters: an insulated system may be required where the flue passes through cold exterior masonry, and a multi-flue cap has to fit a rooftop with several terminations crowded together.
For terminations, top plates, and caps we use DuraFlex OEM or factory-specified stainless components. Mixing aftermarket parts on a listed system can void the liner’s listing and creates fit problems on old oval or oversize flues. We repair the liner and cap where the stainless is sound, and recommend replacement only when the liner is crushed, joint-separated, or improperly sized for the appliance now venting into it. Serving Concourse means working with the parts that actually fit these stacks.
See the difference
Before
After
Before
After
Before
AfterDuraFlex Service Pricing in Concourse
Every job gets a written estimate before any work starts. In Concourse, the price depends on access (a rooftop reached through an interior stair bulkhead is a different day than one with an exterior ladder), the number of flues on a shared stack, the height and condition of the crown, and whether the liner needs repair or replacement. A sealed, dead flue inspection is a smaller job than a live gas flue with a failed termination.
A free estimate includes a Level 2 inspection with camera documentation and photos you can see for yourself. Nothing is recommended without camera evidence, and we’ll tell you plainly when work can safely wait. Call (844) 979-4331 for an exact quote on your Concourse building. Estimates are free.
Serving Concourse, NY – Our Local Coverage Area
We serve Concourse and nearby communities. Use the map below to see the area we cover. If you’re nearby, we can almost certainly help.
FAQs – DuraFlex Chimney Cleaning in Concourse
It covers the whole flue column, top to bottom, not just the apartment where the alarm sounded. A Level 2 inspection traces every appliance tied into the shared stack, checks the liner seams and sizing, examines the top plate and cap on the roof, and inspects the basement cleanout for unsealed coal-era doors. In a shared Concourse stack, a defect on one floor is a building-wide safety issue, so the inspection documents the entire column. Call (844) 979-4331 to book it.
Yes, in most cases, provided the masonry is sound enough to support the liner and the flue is properly sized for the appliance venting into it. Old oval and oversize flues are normal here; the liner has to match the appliance’s venting needs, not just the flue’s dimensions. The inspection determines whether the flue qualifies before any liner goes in. Call (844) 979-4331 for an assessment.
Freeze-thaw cycles and wind on exposed pre-war rooftops loosen cap connections and corrode top plates even when the stainless liner below is sound. The fix is usually a proper stainless top plate and a cap sized to the flue, not a different cap brand. Re-securing a loose cap without checking the top plate underneath often just delays the same failure. Call (844) 979-4331 to have the termination checked.
No. A sealed-off flue still needs a Level 2 inspection to confirm it’s actually sealed, that no gas appliance was later tied into it, and that the cap and crown above it aren’t letting water in. A Level 1 visual check won’t catch a defect in a flue you can’t see into. The inspection is the document that tells you what your flue can safely handle. Call (844) 979-4331 to schedule one.
Often yes, because the crown, not the liner, is the first failure point on these rooftops. Freeze-thaw winters crack mortar crowns and brickwork on exposed chimneys, and a cracked crown lets water in at the top plate. Where the crown is sound, resealing the termination may be all that’s needed; where it’s cracked, crown repair protects the liner investment. Call (844) 979-4331 for a free estimate on your building.
Service Areas Near Concourse
Alongside Concourse, we work in Tremont, University Heights, Bedford Park, Fordham, and West Farms. DuraFlex service in Morrisania and Highbridge runs on the same shared-stack, walk-up reality, so the inspection approach carries over. Same phone line, same written estimate, same Level 2 documentation.
Book Your DuraFlex Service in Concourse Today
Whether you’re a homeowner in a walk-up or a landlord with a stack serving several apartments, a free estimate starts with a Level 2 inspection and photos you can see for yourself. Call (844) 979-4331. We answer 24/7, with fast dispatch from 7am to 7pm, Sunday through Friday.
Written by the team at Chimney Sweep Tremont.